L-GAGE LT7 Series

 
 
Напряжение питания и ток 18 to 30V dc (10% max. ripple)
Range Diffuse:
6% black card:0.5 to 3 m
18% gray card:0.5 to 7 m
90% white card:0.5 to 10 m
Retroreflective:0.5 to 250 m, range is specified using one model BRT-250, BRT-540 and BRT-700 retroreflector
Power Consumption Less than 4.5 W @ 25° C
Measuring Laser Infrared, 900 nm, Class 1
Laser Control Measurement laser is ON when sensor is ON. Pilot (visible) laser enabled during Programming mode, alternates with measurement laser.
Spot Size Diffuse:3 x 10 mm @ 4 m, 4 x 12 mm @ 6 m, 10 x 20 mm @ 10 m
Retroreflective:ø 20 mm @ 10 m; ø 100 mm @ 50 m, ø 200 mm @ 100 m, ø 500 mm @ 250 m
Pilot Laser (Alignment) Visible red, 650 nm, Class 2
Discrete and Analog Output Protection Protected against continuous overload and short circuit
Discrete Output (2) 100 mA, PNP
Discrete Switch Points Adjustable in 1 mm steps
Discrete Output Hysteresis Adjustable, 10 mm min.
Alarm Outputs 50 mA, PNP (NO)
Analog Output Diffuse:4-20 mA
Retroreflective:none
Maximum Cable Length 100 m
Выходной время отклика 12 milliseconds
Линейность ±10 mm
Resolution/Repeatability Diffuse:±4 mm
Retroreflective:±2 mm
Color Sensitivity Diffuse:contact factory
Retroreflective:not applicable
Температурный Эффект less than ±5 mm over the total sensing range
Minimum Analog Window Size Diffuse:300 mm
Retroreflective:none
регулировка Push-button-directed password enable/disable, measurement unit select, offset value select, output limits set, output mode select, analog output slope select (diffuse models only) and output limit manual adjust. See data sheet for information.
Serial Interface RS-422 or SSI compatible
Serial Measurement Speed SSI:1.4 milliseconds (SSI cycle 80 microseconds)
RS-422:2.9 milliseconds @ 57.6 kBaud
индикатор 2-line digital LCD display. See data sheet for more information. 4 LED indicators:
Green:Power ON/OFF
Red:Alarm (Error) LED
Orange:Output 1 and Output 2 conducting LEDs
конструкция ABS shock-resistant housing; PMMA window; polycarbonate displays
Weight Approx. 230 g
Степень защиты IEC IP67
соединение 12-pin M16 connector; 100 m max. cable length. QD cables are ordered separately.
Условия эксплуатации Temperature:-10° to +50° C in continuous operation
Температура хранения -30° to +75° C
Vibration Shock EN 60947-5-2
Рекомендации по применению • All specifications are based on the specified surface at constant ambient conditions and following a minimum operating time of 15 minutes.







• For best accuracy, allow a 15-minute warmup before programming or operating







Crosstalk avoidance: Light spots must be separated by at least 200 mm.
Арт.

  • Offered in retroreflective models with two discrete outputs (PNP) for extremely long ranges up to 250 m
  • Available in diffuse models with two discrete outputs (PNP) and one 4-20 mA output for long-range background suppression up to 10 m
  • Provides two alarm outputs with ongoing LCD display for easy troubleshooting
  • Features TEACH-mode programming, using integrated push buttons or serial interface
  • Continually displays sensing distance in millimeters or hundredths of an inch
  • Delivers excellent ±10 mm linearity
  • Offers choice of RS-422 or SSI-compatible serial connection
  • Uses visible Class 2 alignment laser for accurate alignment
  • Provides quick warmup to minimize drift