The MKAS Compact analyzer system is a complete measuring system in a compact wall-mounting enclosure. The space-saving cabinet was designed for a maximum of 2 S710 or SIDOR analyzers and a compact gas conditioning unit. The system fulfills all requirements for an automatic measuring system. It can also be modified with additional components.
At a glance
| Compact analyzer cabinet |
| For maximum 2 S710 or SIDOR analyzers or NOx converter |
| Includes the major system components |
| Wired and tested - ready for use |
Your benefits
| Space-saving complete system |
| Adaptable to the measuring task due to modular concept |
| Proven system components offer a reliable solution |
| Fulfills the requirements for an automatic measuring system according to EU standards, especially EN 15267-3 |
Fields of application
| Emission monitoring, also according to EU directives |
| Measurement in raw and clean gas |
| Measurement in process gases |
| Technical data | |||
| Analyzer: | S700, SIDOR | ||
| Measured values: | CH4, CO, CO2, N2O, NO, NO2, O2, SO2 | ||
| Comment: | Measuring ranges depend on integrated analyzer and application | ||
| Gas flow rate: | 30 ... 60 l/h | ||
| Температура процесса: | Inlet analyzer system: 0 ... +200 °C Process: 0 ... +900 °C depending on sampling probe |
||
| Process gas humidity: | Dew point: ≤+65 °C | ||
| Ambient temperature: | With cooling device: +5 ... +50 °C Standard: +5 ... +35 °C without direct sun exposure |
||
| Ambient humidity: | 0 ... 95 % relative humidity; non-condensing |
||
| Electrical safety: | CE | ||
| Enclosure rating: | With cooling device: IP 34 for outer cooling circuit Standard: IP 54 |
||
| Analog outputs: | Depending on analyzer and system configuration | ||
| Analog inputs: | Depending on analyzer and system configuration | ||
| Digital outputs: | Depending on analyzer and system configuration | ||
| Digital inputs: | Depending on analyzer and system configuration | ||
| Interfaces: | RS-485 (option) | ||
| Device version: | Steel sheet cabinet | ||
| System components: | SIDOR or S710 analyzer Analyzer cabinet Sampling probe Cooling device (option) Sample gas cooler Sample gas line NOx-converter (option) |
||
| Mounting: | Under roofing or other protection against exposure to direct heat radiation, high dust loads and corrosive atmospheres | ||