No matter whether monitoring of transmission, opacity, extinction or dust concentration is required, the FW300 Ex dust measuring device can take care of it. Each measured quantity can be freely selected. The FW300 Ex measures immediate and precise even during difficult conditions such as sticky dust loads, high gas temperatures or variation in gas velocities. Device types with flameproof or dustproof housings are available for applications in potentially explosive atmospheres.
At a glance
For medium to high dust concentrations |
Automatic check cycle for zero and reference point |
Device type for hazardous areas Zone 1, 2 and 22 |
For small to medium measuring distances |
Your benefits
Simple operation |
Very low maintenance effort |
Measurement in potentially explosive atmospheres |
Fields of application
Filter plant monitoring for filter breaks |
Monitoring of dust loads in factory buildings |
Emission monitoring in industry plants |
Measurement of the dust emissions on garbage dumps, in quarries and mill works |
Technical data | |||
Measurement principles: | Transmittance measurement | ||
Measured values: | Extinction Opacity Dust concentration Transmittance |
||
Measuring ranges: | Extinction: 0 ... 0.1 Ext / 0 ... 2.5 Ext Opacity: 0 ... 20 % / 0 ... 100 % Dust concentration: 0 ... 13 mg/m3 / 0 ... 12,000 mg/m³ Transmittance: 100 ... 80 % / 100 ... 0 % |
||
Comment: | The measurement depends on measuring distance and dust properties | ||
Температура процесса: | 0 ... +600 °C | ||
Давление процесса: | -50 ... 30 hPa | ||
Process gas humidity: |
non-condensing |
||
Duct diameter: | 0.5 ... 2 m 1.5 ... 8 m |
||
Ambient temperature: | -20 ... +40 °C | ||
Ex-approvals ATEX: | AK1-Ex connection unit: II 2G Ex de IIC T6, AK1-Ex22 connection unit: II 2D Ex tD A21 T80°C IP6x, Sender/receiver unit and rotating reflector (ATEX Ex-zone 1 and 2): II 2G Ex IIC T6, Sender/receiver unit and rotating reflector (ATEX Ex-zone 22): II 3D Ex t IIIB T80°C Dc IP54 | ||
Electrical safety: | CE | ||
Enclosure rating: | IP 65 | ||
Analog outputs: | 1 output: 0/2/4 ... 20 mA, 750 Ω electrically isolated; second output as option |
||
Digital outputs: | 3 relay contacts: 48 V, 1 A potential-free; for status signals "operation/ failure", "limit value", "maintenance" |
||
Digital inputs: | 1 input potential-free; for maintenance switch |
||
Interfaces: | RS-232 (service interface) | ||
Bus protocol: | CAN (option) for connection of an evaluation unit |
||
Operation: | Via software SOPAS ET | ||
System components: | Connection unit Reflector unit Sender/receiver unit |
||
Test functions: | Automatic self-test (linearity, drift, aging) Manual linearity check with reference filter |
||
Options: | External purge air unit |