At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
| Performance | |||
| Measuring length: | 0 m ... 38 m | ||
| Measuring range: | 38 m | ||
| Resolution: | 0.1 mm | ||
| Piston speed: | 6.6 m/s 1) | ||
| Measurement accuracy: | ± 1000 + ME (Tu-25° C) Tk µm 2) | ||
| Repeatability (Ta not constant): | 0.3 mm | ||
| Mechanical data | |||
| Тип подключения: | Connector M23, 12-pin | ||
| Масса: | 2.4 kg | ||
| Position tolerance: | ± 10 mm | ||
| Material: | AlMgSiPbF28 | ||
| Electrical data | |||
| Время инициализации: | 2 s | ||
| Время формирования позици: | 0.8 ms | ||
| Supply voltage: | 10 V ... 32 V | ||
| Потребляемая мощность: | 250 mA | ||
| MTTFd: mean time to dangerous failure: | 45 a (EN ISO 13849) 1) | ||
| Interfaces | |||
| Electrical interface: | SSI | ||
| Interface signals: | Digital, serial | ||
| Интерфейс для параметризации: | Data format: 1 start bit, 8 data bits, 1 stop bit, no parity, Data protocol: ASCII, Baud rate 9600 RS-422, RS-422, Four wire transmission, asynchrony, full duplex | ||
| Data format: | SSI 24 bits format | ||
| Standard (default setting SSI standard): | RS-422 off | ||
| Данные окуражающей среды | |||
| EMC: | (according to EN 61000-6-2 and EN 61000-6-4) 1) | ||
| Enclosure rating: | IP 65 (IEC 60529), with mating connector inserted | ||
| Working temperature range: | -20 °C ... +60 °C | ||
| Storage temperature range: | -40 °C ... +85 °C | ||
| Устойчивость к ударам: | 30 g, 10 ms (DIN EN 60 068-2-27) | ||
| Resistance to vibration: | 10 g, 20 Hz ... 250 Hz (EN 60068-2-6) | ||
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
| Performance | |||
| Measuring length: | 0 m ... 54 m | ||
| Measuring range: | 54 m | ||
| Resolution: | 0.1 mm | ||
| Piston speed: | 6.6 m/s 1) | ||
| Measurement accuracy: | ± 2000 + ME (Tu-25° C) Tk µm 2) | ||
| Repeatability (Ta not constant): | 1 mm | ||
| Mechanical data | |||
| Тип подключения: | Connector M23, 12-pin | ||
| Масса: | 4.4 kg | ||
| Position tolerance: | ± 20 mm | ||
| Material: | AlMgSiPbF28 | ||
| Electrical data | |||
| Время инициализации: | 2 s | ||
| Время формирования позици: | 0.8 ms | ||
| Supply voltage: | 10 V ... 32 V | ||
| Потребляемая мощность: | 250 mA | ||
| MTTFd: mean time to dangerous failure: | 34 a (EN ISO 13849) 1) | ||
| Interfaces | |||
| Electrical interface: | SSI | ||
| Interface signals: | Digital, serial | ||
| Интерфейс для параметризации: | Data format: 1 start bit, 8 data bits, 1 stop bit, no parity, Data protocol: ASCII, Baud rate 9600 RS-422, RS-422, Four wire transmission, asynchrony, full duplex | ||
| Data format: | SSI 24 bits format | ||
| Standard (default setting SSI standard): | RS-422 off | ||
| Данные окуражающей среды | |||
| EMC: | (according to EN 61000-6-2 and EN 61000-6-4) 1) | ||
| Enclosure rating: | IP 65 (IEC 60529), with mating connector inserted | ||
| Working temperature range: | -30 °C ... +70 °C | ||
| Storage temperature range: | -40 °C ... +85 °C | ||
| Устойчивость к ударам: | 30 g, 10 ms (DIN EN 60 068-2-27) | ||
| Resistance to vibration: | 10 g, 20 Hz ... 250 Hz (EN 60068-2-6) | ||
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
| Performance | |||
| Measuring length: | 0 m ... 107 m | ||
| Measuring range: | 107 m | ||
| Resolution: | 0.1 mm | ||
| Piston speed: | 6.6 m/s 1) | ||
| Measurement accuracy: | ± 1000 + ME (Tu-25° C) Tk µm 2) | ||
| Repeatability (Ta not constant): | 0.3 mm | ||
| Mechanical data | |||
| Тип подключения: | Connector M23, 12-pin | ||
| Масса: | 2.7 kg | ||
| Position tolerance: | ± 10 mm | ||
| Material: | AlMgSiPbF28 | ||
| Electrical data | |||
| Время инициализации: | 2 s | ||
| Время формирования позици: | 0.8 ms | ||
| Supply voltage: | 10 V ... 32 V | ||
| Потребляемая мощность: | 250 mA | ||
| MTTFd: mean time to dangerous failure: | 40 a (EN ISO 13849) 1) | ||
| Interfaces | |||
| Electrical interface: | SSI | ||
| Interface signals: | Digital, serial | ||
| Интерфейс для параметризации: | Data format: 1 start bit, 8 data bits, 1 stop bit, no parity, Data protocol: ASCII, Baud rate 9600 RS-422, RS-422, Four wire transmission, asynchrony, full duplex | ||
| Data format: | SSI 24 bits format | ||
| Standard (default setting SSI standard): | RS-422 off | ||
| Данные окуражающей среды | |||
| EMC: | (according to EN 61000-6-2 and EN 61000-6-4) 1) | ||
| Enclosure rating: | IP 65 (IEC 60529), with mating connector inserted | ||
| Working temperature range: | -20 °C ... +60 °C | ||
| Storage temperature range: | -40 °C ... +85 °C | ||
| Устойчивость к ударам: | 30 g, 10 ms (DIN EN 60 068-2-27) | ||
| Resistance to vibration: | 10 g, 20 Hz ... 250 Hz (EN 60068-2-6) | ||
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
| Performance | |||
| Measuring length: | 0 m ... 354 m | ||
| Measuring range: | 354 m | ||
| Resolution: | 0.1 mm | ||
| Piston speed: | 6.6 m/s 1) | ||
| Measurement accuracy: | ± 1000 + ME (Tu-25° C) Tk µm 2) | ||
| Repeatability (Ta not constant): | 0.3 mm | ||
| Mechanical data | |||
| Тип подключения: | Connector M23, 12-pin | ||
| Масса: | 3.6 kg | ||
| Position tolerance: | ± 10 mm | ||
| Material: | AlMgSiPbF28 | ||
| Electrical data | |||
| Время инициализации: | 2 s | ||
| Время формирования позици: | 0.8 ms | ||
| Supply voltage: | 10 V ... 32 V | ||
| Потребляемая мощность: | 250 mA | ||
| MTTFd: mean time to dangerous failure: | 31 a (EN ISO 13849) 1) | ||
| Interfaces | |||
| Electrical interface: | SSI | ||
| Interface signals: | Digital, serial | ||
| Интерфейс для параметризации: | Data format: 1 start bit, 8 data bits, 1 stop bit, no parity, Data protocol: ASCII, Baud rate 9600 RS-422, RS-422, Four wire transmission, asynchrony, full duplex | ||
| Data format: | SSI 24 bits format | ||
| Standard (default setting SSI standard): | RS-422 off | ||
| Данные окуражающей среды | |||
| EMC: | (according to EN 61000-6-2 and EN 61000-6-4) 1) | ||
| Enclosure rating: | IP 65 (IEC 60529), with mating connector inserted | ||
| Working temperature range: | -20 °C ... +60 °C | ||
| Storage temperature range: | -40 °C ... +85 °C | ||
| Устойчивость к ударам: | 30 g, 10 ms (DIN EN 60 068-2-27) | ||
| Resistance to vibration: | 10 g, 20 Hz ... 250 Hz (EN 60068-2-6) | ||
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
| Performance | |||
| Measuring length: | 0 m ... 548 m | ||
| Measuring range: | 548 m | ||
| Resolution: | 0.1 mm | ||
| Piston speed: | 6.6 m/s 1) | ||
| Measurement accuracy: | ± 2000 + ME (Tu-25° C) Tk µm 2) | ||
| Repeatability (Ta not constant): | 1 mm | ||
| Mechanical data | |||
| Тип подключения: | Connector M23, 12-pin | ||
| Масса: | 6.7 kg | ||
| Position tolerance: | ± 20 mm | ||
| Material: | AlMgSiPbF28 | ||
| Electrical data | |||
| Время инициализации: | 2 s | ||
| Время формирования позици: | 0.8 ms | ||
| Supply voltage: | 10 V ... 32 V | ||
| Потребляемая мощность: | 250 mA | ||
| MTTFd: mean time to dangerous failure: | 22 a (EN ISO 13849) 1) | ||
| Interfaces | |||
| Electrical interface: | SSI | ||
| Interface signals: | Digital, serial | ||
| Интерфейс для параметризации: | Data format: 1 start bit, 8 data bits, 1 stop bit, no parity, Data protocol: ASCII, Baud rate 9600 RS-422, RS-422, Four wire transmission, asynchrony, full duplex | ||
| Data format: | SSI 24 bits format | ||
| Standard (default setting SSI standard): | RS-422 off | ||
| Данные окуражающей среды | |||
| EMC: | (according to EN 61000-6-2 and EN 61000-6-4) 1) | ||
| Enclosure rating: | IP 65 (IEC 60529), with mating connector inserted | ||
| Working temperature range: | -30 °C ... +70 °C | ||
| Storage temperature range: | -40 °C ... +85 °C | ||
| Устойчивость к ударам: | 30 g, 10 ms (DIN EN 60 068-2-27) | ||
| Resistance to vibration: | 10 g, 20 Hz ... 250 Hz (EN 60068-2-6) | ||
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
| Performance | |||
| Measuring length: | 0 m ... 1,700 m | ||
| Measuring range: | 1,700 m | ||
| Resolution: | 0.1 mm | ||
| Piston speed: | 6.6 m/s 1) | ||
| Measurement accuracy: | ± 1000 + ME (Tu-25° C) Tk µm 2) | ||
| Repeatability (Ta not constant): | 0.3 mm | ||
| Mechanical data | |||
| Тип подключения: | Connector M23, 12-pin | ||
| Масса: | 5.2 kg | ||
| Position tolerance: | ± 10 mm | ||
| Material: | AlMgSiPbF28 | ||
| Electrical data | |||
| Время инициализации: | 2 s | ||
| Время формирования позици: | 0.8 ms | ||
| Supply voltage: | 10 V ... 32 V | ||
| Потребляемая мощность: | 250 mA | ||
| MTTFd: mean time to dangerous failure: | 21 a (EN ISO 13849) 1) | ||
| Interfaces | |||
| Electrical interface: | SSI | ||
| Interface signals: | Digital, serial | ||
| Интерфейс для параметризации: | Data format: 1 start bit, 8 data bits, 1 stop bit, no parity, Data protocol: ASCII, Baud rate 9600 RS-422, RS-422, Four wire transmission, asynchrony, full duplex | ||
| Data format: | SSI 24 bits format | ||
| Standard (default setting SSI standard): | RS-422 off | ||
| Данные окуражающей среды | |||
| EMC: | (according to EN 61000-6-2 and EN 61000-6-4) 1) | ||
| Enclosure rating: | IP 65 (IEC 60529), with mating connector inserted | ||
| Working temperature range: | -20 °C ... +60 °C | ||
| Storage temperature range: | -40 °C ... +85 °C | ||
| Устойчивость к ударам: | 30 g, 10 ms (DIN EN 60 068-2-27) | ||
| Resistance to vibration: | 10 g, 20 Hz ... 250 Hz (EN 60068-2-6) | ||
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
| Performance | |||
| Measuring length: | 0 m ... 38 m | ||
| Measuring range: | 38 m | ||
| Resolution: | 0.1 mm | ||
| Piston speed: | 6.6 m/s 1) | ||
| Measurement accuracy: | ± 1000 + ME (Tu-25° C) Tk µm 2) | ||
| Repeatability (Ta not constant): | 0.3 mm | ||
| Mechanical data | |||
| Тип подключения: | Cable, 1.5 m | ||
| Масса: | 2.4 kg | ||
| Position tolerance: | ± 10 mm | ||
| Material: | AlMgSiPbF28 | ||
| Electrical data | |||
| Время инициализации: | 2 s | ||
| Время формирования позици: | 0.8 ms | ||
| Supply voltage: | 10 V ... 32 V | ||
| Потребляемая мощность: | 250 mA | ||
| MTTFd: mean time to dangerous failure: | 45 a (EN ISO 13849) 1) | ||
| Interfaces | |||
| Electrical interface: | SSI | ||
| Interface signals: | Digital, serial | ||
| Интерфейс для параметризации: | Data format: 1 start bit, 8 data bits, 1 stop bit, no parity, Data protocol: ASCII, Baud rate 9600 RS-422, RS-422, Four wire transmission, asynchrony, full duplex | ||
| Data format: | SSI 24 bits format | ||
| Standard (default setting SSI standard): | RS-422 off | ||
| Данные окуражающей среды | |||
| EMC: | (according to EN 61000-6-2 and EN 61000-6-4) 1) | ||
| Enclosure rating: | IP 66 (IEC 60529) | ||
| Working temperature range: | -20 °C ... +60 °C | ||
| Storage temperature range: | -40 °C ... +85 °C | ||
| Устойчивость к ударам: | 30 g, 10 ms (DIN EN 60 068-2-27) | ||
| Resistance to vibration: | 10 g, 20 Hz ... 250 Hz (EN 60068-2-6) | ||
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
| Performance | |||
| Measuring length: | 0 m ... 107 m | ||
| Measuring range: | 107 m | ||
| Resolution: | 0.1 mm | ||
| Piston speed: | 6.6 m/s 1) | ||
| Measurement accuracy: | ± 1000 + ME (Tu-25° C) Tk µm 2) | ||
| Repeatability (Ta not constant): | 0.3 mm | ||
| Mechanical data | |||
| Тип подключения: | Cable, 1.5 m | ||
| Масса: | 2.7 kg | ||
| Position tolerance: | ± 10 mm | ||
| Material: | AlMgSiPbF28 | ||
| Electrical data | |||
| Время инициализации: | 2 s | ||
| Время формирования позици: | 0.8 ms | ||
| Supply voltage: | 10 V ... 32 V | ||
| Потребляемая мощность: | 250 mA | ||
| MTTFd: mean time to dangerous failure: | 40 a (EN ISO 13849) 1) | ||
| Interfaces | |||
| Electrical interface: | SSI | ||
| Interface signals: | Digital, serial | ||
| Интерфейс для параметризации: | Data format: 1 start bit, 8 data bits, 1 stop bit, no parity, Data protocol: ASCII, Baud rate 9600 RS-422, RS-422, Four wire transmission, asynchrony, full duplex | ||
| Data format: | SSI 24 bits format | ||
| Standard (default setting SSI standard): | RS-422 off | ||
| Данные окуражающей среды | |||
| EMC: | (according to EN 61000-6-2 and EN 61000-6-4) 1) | ||
| Enclosure rating: | IP 66 (IEC 60529) | ||
| Working temperature range: | -20 °C ... +60 °C | ||
| Storage temperature range: | -40 °C ... +85 °C | ||
| Устойчивость к ударам: | 30 g, 10 ms (DIN EN 60 068-2-27) | ||
| Resistance to vibration: | 10 g, 20 Hz ... 250 Hz (EN 60068-2-6) | ||
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
| Performance | |||
| Measuring length: | 0 m ... 354 m | ||
| Measuring range: | 354 m | ||
| Resolution: | 0.1 mm | ||
| Piston speed: | 6.6 m/s 1) | ||
| Measurement accuracy: | ± 1000 + ME (Tu-25° C) Tk µm 2) | ||
| Repeatability (Ta not constant): | 0.3 mm | ||
| Mechanical data | |||
| Тип подключения: | Cable, 1.5 m | ||
| Масса: | 3.6 kg | ||
| Position tolerance: | ± 10 mm | ||
| Material: | AlMgSiPbF28 | ||
| Electrical data | |||
| Время инициализации: | 2 s | ||
| Время формирования позици: | 0.8 ms | ||
| Supply voltage: | 10 V ... 32 V | ||
| Потребляемая мощность: | 250 mA | ||
| MTTFd: mean time to dangerous failure: | 31 a (EN ISO 13849) 1) | ||
| Interfaces | |||
| Electrical interface: | SSI | ||
| Interface signals: | Digital, serial | ||
| Интерфейс для параметризации: | Data format: 1 start bit, 8 data bits, 1 stop bit, no parity, Data protocol: ASCII, Baud rate 9600 RS-422, RS-422, Four wire transmission, asynchrony, full duplex | ||
| Data format: | SSI 24 bits format | ||
| Standard (default setting SSI standard): | RS-422 off | ||
| Данные окуражающей среды | |||
| EMC: | (according to EN 61000-6-2 and EN 61000-6-4) 1) | ||
| Enclosure rating: | IP 66 (IEC 60529) | ||
| Working temperature range: | -20 °C ... +60 °C | ||
| Storage temperature range: | -40 °C ... +85 °C | ||
| Устойчивость к ударам: | 30 g, 10 ms (DIN EN 60 068-2-27) | ||
| Resistance to vibration: | 10 g, 20 Hz ... 250 Hz (EN 60068-2-6) | ||
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
| Performance | |||
| Measuring length: | 0 m ... 1,700 m | ||
| Measuring range: | 1,700 m | ||
| Resolution: | 0.1 mm | ||
| Piston speed: | 6.6 m/s 1) | ||
| Measurement accuracy: | ± 1000 + ME (Tu-25° C) Tk µm 2) | ||
| Repeatability (Ta not constant): | 0.3 mm | ||
| Mechanical data | |||
| Тип подключения: | Cable, 1.5 m | ||
| Масса: | 5.2 kg | ||
| Position tolerance: | ± 10 mm | ||
| Material: | AlMgSiPbF28 | ||
| Electrical data | |||
| Время инициализации: | 2 s | ||
| Время формирования позици: | 0.8 ms | ||
| Supply voltage: | 10 V ... 32 V | ||
| Потребляемая мощность: | 250 mA | ||
| MTTFd: mean time to dangerous failure: | 21 a (EN ISO 13849) 1) | ||
| Interfaces | |||
| Electrical interface: | SSI | ||
| Interface signals: | Digital, serial | ||
| Интерфейс для параметризации: | Data format: 1 start bit, 8 data bits, 1 stop bit, no parity, Data protocol: ASCII, Baud rate 9600 RS-422, RS-422, Four wire transmission, asynchrony, full duplex | ||
| Data format: | SSI 24 bits format | ||
| Standard (default setting SSI standard): | RS-422 off | ||
| Данные окуражающей среды | |||
| EMC: | (according to EN 61000-6-2 and EN 61000-6-4) 1) | ||
| Enclosure rating: | IP 66 (IEC 60529) | ||
| Working temperature range: | -20 °C ... +60 °C | ||
| Storage temperature range: | -40 °C ... +85 °C | ||
| Устойчивость к ударам: | 30 g, 10 ms (DIN EN 60 068-2-27) | ||
| Resistance to vibration: | 10 g, 20 Hz ... 250 Hz (EN 60068-2-6) | ||
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
| Performance | |||
| Measuring length: | 0 m ... 38 m | ||
| Measuring range: | 38 m | ||
| Resolution: | 0.1 mm | ||
| Piston speed: | 6.6 m/s 1) | ||
| Measurement accuracy: | ± 1000 + ME (Tu-25° C) Tk µm 2) | ||
| Repeatability (Ta not constant): | 0.3 mm | ||
| Mechanical data | |||
| Тип подключения: | Cable, 3 m | ||
| Масса: | 2.4 kg | ||
| Position tolerance: | ± 10 mm | ||
| Material: | AlMgSiPbF28 | ||
| Electrical data | |||
| Время инициализации: | 2 s | ||
| Время формирования позици: | 0.8 ms | ||
| Supply voltage: | 10 V ... 32 V | ||
| Потребляемая мощность: | 250 mA | ||
| MTTFd: mean time to dangerous failure: | 45 a (EN ISO 13849) 1) | ||
| Interfaces | |||
| Electrical interface: | SSI | ||
| Interface signals: | Digital, serial | ||
| Интерфейс для параметризации: | Data format: 1 start bit, 8 data bits, 1 stop bit, no parity, Data protocol: ASCII, Baud rate 9600 RS-422, RS-422, Four wire transmission, asynchrony, full duplex | ||
| Data format: | SSI 24 bits format | ||
| Standard (default setting SSI standard): | RS-422 off | ||
| Данные окуражающей среды | |||
| EMC: | (according to EN 61000-6-2 and EN 61000-6-4) 1) | ||
| Enclosure rating: | IP 66 (IEC 60529) | ||
| Working temperature range: | -20 °C ... +60 °C | ||
| Storage temperature range: | -40 °C ... +85 °C | ||
| Устойчивость к ударам: | 30 g, 10 ms (DIN EN 60 068-2-27) | ||
| Resistance to vibration: | 10 g, 20 Hz ... 250 Hz (EN 60068-2-6) | ||
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
| Performance | |||
| Measuring length: | 0 m ... 107 m | ||
| Measuring range: | 107 m | ||
| Resolution: | 0.1 mm | ||
| Piston speed: | 6.6 m/s 1) | ||
| Measurement accuracy: | ± 1000 + ME (Tu-25° C) Tk µm 2) | ||
| Repeatability (Ta not constant): | 0.3 mm | ||
| Mechanical data | |||
| Тип подключения: | Cable, 3 m | ||
| Масса: | 2.7 kg | ||
| Position tolerance: | ± 10 mm | ||
| Material: | AlMgSiPbF28 | ||
| Electrical data | |||
| Время инициализации: | 2 s | ||
| Время формирования позици: | 0.8 ms | ||
| Supply voltage: | 10 V ... 32 V | ||
| Потребляемая мощность: | 250 mA | ||
| MTTFd: mean time to dangerous failure: | 40 a (EN ISO 13849) 1) | ||
| Interfaces | |||
| Electrical interface: | SSI | ||
| Interface signals: | Digital, serial | ||
| Интерфейс для параметризации: | Data format: 1 start bit, 8 data bits, 1 stop bit, no parity, Data protocol: ASCII, Baud rate 9600 RS-422, RS-422, Four wire transmission, asynchrony, full duplex | ||
| Data format: | SSI 24 bits format | ||
| Standard (default setting SSI standard): | RS-422 off | ||
| Данные окуражающей среды | |||
| EMC: | (according to EN 61000-6-2 and EN 61000-6-4) 1) | ||
| Enclosure rating: | IP 66 (IEC 60529) | ||
| Working temperature range: | -20 °C ... +60 °C | ||
| Storage temperature range: | -40 °C ... +85 °C | ||
| Устойчивость к ударам: | 30 g, 10 ms (DIN EN 60 068-2-27) | ||
| Resistance to vibration: | 10 g, 20 Hz ... 250 Hz (EN 60068-2-6) | ||
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
| Performance | |||
| Measuring length: | 0 m ... 354 m | ||
| Measuring range: | 354 m | ||
| Resolution: | 0.1 mm | ||
| Piston speed: | 6.6 m/s 1) | ||
| Measurement accuracy: | ± 1000 + ME (Tu-25° C) Tk µm 2) | ||
| Repeatability (Ta not constant): | 0.3 mm | ||
| Mechanical data | |||
| Тип подключения: | Cable, 3 m | ||
| Масса: | 3.6 kg | ||
| Position tolerance: | ± 10 mm | ||
| Material: | AlMgSiPbF28 | ||
| Electrical data | |||
| Время инициализации: | 2 s | ||
| Время формирования позици: | 0.8 ms | ||
| Supply voltage: | 10 V ... 32 V | ||
| Потребляемая мощность: | 250 mA | ||
| MTTFd: mean time to dangerous failure: | 31 a (EN ISO 13849) 1) | ||
| Interfaces | |||
| Electrical interface: | SSI | ||
| Interface signals: | Digital, serial | ||
| Интерфейс для параметризации: | Data format: 1 start bit, 8 data bits, 1 stop bit, no parity, Data protocol: ASCII, Baud rate 9600 RS-422, RS-422, Four wire transmission, asynchrony, full duplex | ||
| Data format: | SSI 24 bits format | ||
| Standard (default setting SSI standard): | RS-422 off | ||
| Данные окуражающей среды | |||
| EMC: | (according to EN 61000-6-2 and EN 61000-6-4) 1) | ||
| Enclosure rating: | IP 66 (IEC 60529) | ||
| Working temperature range: | -20 °C ... +60 °C | ||
| Storage temperature range: | -40 °C ... +85 °C | ||
| Устойчивость к ударам: | 30 g, 10 ms (DIN EN 60 068-2-27) | ||
| Resistance to vibration: | 10 g, 20 Hz ... 250 Hz (EN 60068-2-6) | ||
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
| Performance | |||
| Measuring length: | 0 m ... 1,700 m | ||
| Measuring range: | 1,700 m | ||
| Resolution: | 0.1 mm | ||
| Piston speed: | 6.6 m/s 1) | ||
| Measurement accuracy: | ± 1000 + ME (Tu-25° C) Tk µm 2) | ||
| Repeatability (Ta not constant): | 0.3 mm | ||
| Mechanical data | |||
| Тип подключения: | Cable, 3 m | ||
| Масса: | 5.2 kg | ||
| Position tolerance: | ± 10 mm | ||
| Material: | AlMgSiPbF28 | ||
| Electrical data | |||
| Время инициализации: | 2 s | ||
| Время формирования позици: | 0.8 ms | ||
| Supply voltage: | 10 V ... 32 V | ||
| Потребляемая мощность: | 250 mA | ||
| MTTFd: mean time to dangerous failure: | 21 a (EN ISO 13849) 1) | ||
| Interfaces | |||
| Electrical interface: | SSI | ||
| Interface signals: | Digital, serial | ||
| Интерфейс для параметризации: | Data format: 1 start bit, 8 data bits, 1 stop bit, no parity, Data protocol: ASCII, Baud rate 9600 RS-422, RS-422, Four wire transmission, asynchrony, full duplex | ||
| Data format: | SSI 24 bits format | ||
| Standard (default setting SSI standard): | RS-422 off | ||
| Данные окуражающей среды | |||
| EMC: | (according to EN 61000-6-2 and EN 61000-6-4) 1) | ||
| Enclosure rating: | IP 66 (IEC 60529) | ||
| Working temperature range: | -20 °C ... +60 °C | ||
| Storage temperature range: | -40 °C ... +85 °C | ||
| Устойчивость к ударам: | 30 g, 10 ms (DIN EN 60 068-2-27) | ||
| Resistance to vibration: | 10 g, 20 Hz ... 250 Hz (EN 60068-2-6) | ||
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
| Performance | |||
| Measuring length: | 0 m ... 38 m | ||
| Measuring range: | 38 m | ||
| Resolution: | 0.1 mm | ||
| Piston speed: | 6.6 m/s 1) | ||
| Measurement accuracy: | ± 1000 + ME (Tu-25° C) Tk µm 2) | ||
| Repeatability (Ta not constant): | 0.3 mm | ||
| Mechanical data | |||
| Тип подключения: | Cable, 5 m | ||
| Масса: | 2.4 kg | ||
| Position tolerance: | ± 10 mm | ||
| Material: | AlMgSiPbF28 | ||
| Electrical data | |||
| Время инициализации: | 2 s | ||
| Время формирования позици: | 0.8 ms | ||
| Supply voltage: | 10 V ... 32 V | ||
| Потребляемая мощность: | 250 mA | ||
| MTTFd: mean time to dangerous failure: | 45 a (EN ISO 13849) 1) | ||
| Interfaces | |||
| Electrical interface: | SSI | ||
| Interface signals: | Digital, serial | ||
| Интерфейс для параметризации: | Data format: 1 start bit, 8 data bits, 1 stop bit, no parity, Data protocol: ASCII, Baud rate 9600 RS-422, RS-422, Four wire transmission, asynchrony, full duplex | ||
| Data format: | SSI 24 bits format | ||
| Standard (default setting SSI standard): | RS-422 off | ||
| Данные окуражающей среды | |||
| EMC: | (according to EN 61000-6-2 and EN 61000-6-4) 1) | ||
| Enclosure rating: | IP 66 (IEC 60529) | ||
| Working temperature range: | -20 °C ... +60 °C | ||
| Storage temperature range: | -40 °C ... +85 °C | ||
| Устойчивость к ударам: | 30 g, 10 ms (DIN EN 60 068-2-27) | ||
| Resistance to vibration: | 10 g, 20 Hz ... 250 Hz (EN 60068-2-6) | ||
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
| Performance | |||
| Measuring length: | 0 m ... 54 m | ||
| Measuring range: | 54 m | ||
| Resolution: | 0.1 mm | ||
| Piston speed: | 6.6 m/s 1) | ||
| Measurement accuracy: | ± 2000 + ME (Tu-25° C) Tk µm 2) | ||
| Repeatability (Ta not constant): | 1 mm | ||
| Mechanical data | |||
| Тип подключения: | Cable, 5 m | ||
| Масса: | 4.4 kg | ||
| Position tolerance: | ± 20 mm | ||
| Material: | AlMgSiPbF28 | ||
| Electrical data | |||
| Время инициализации: | 2 s | ||
| Время формирования позици: | 0.8 ms | ||
| Supply voltage: | 10 V ... 32 V | ||
| Потребляемая мощность: | 250 mA | ||
| MTTFd: mean time to dangerous failure: | 34 a (EN ISO 13849) 1) | ||
| Interfaces | |||
| Electrical interface: | SSI | ||
| Interface signals: | Digital, serial | ||
| Интерфейс для параметризации: | Data format: 1 start bit, 8 data bits, 1 stop bit, no parity, Data protocol: ASCII, Baud rate 9600 RS-422, RS-422, Four wire transmission, asynchrony, full duplex | ||
| Data format: | SSI 24 bits format | ||
| Standard (default setting SSI standard): | RS-422 off | ||
| Данные окуражающей среды | |||
| EMC: | (according to EN 61000-6-2 and EN 61000-6-4) 1) | ||
| Enclosure rating: | IP 66 (IEC 60529) | ||
| Working temperature range: | -30 °C ... +70 °C | ||
| Storage temperature range: | -40 °C ... +85 °C | ||
| Устойчивость к ударам: | 30 g, 10 ms (DIN EN 60 068-2-27) | ||
| Resistance to vibration: | 10 g, 20 Hz ... 250 Hz (EN 60068-2-6) | ||
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
| Performance | |||
| Measuring length: | 0 m ... 107 m | ||
| Measuring range: | 107 m | ||
| Resolution: | 0.1 mm | ||
| Piston speed: | 6.6 m/s 1) | ||
| Measurement accuracy: | ± 1000 + ME (Tu-25° C) Tk µm 2) | ||
| Repeatability (Ta not constant): | 0.3 mm | ||
| Mechanical data | |||
| Тип подключения: | Cable, 5 m | ||
| Масса: | 2.7 kg | ||
| Position tolerance: | ± 10 mm | ||
| Material: | AlMgSiPbF28 | ||
| Electrical data | |||
| Время инициализации: | 2 s | ||
| Время формирования позици: | 0.8 ms | ||
| Supply voltage: | 10 V ... 32 V | ||
| Потребляемая мощность: | 250 mA | ||
| MTTFd: mean time to dangerous failure: | 40 a (EN ISO 13849) 1) | ||
| Interfaces | |||
| Electrical interface: | SSI | ||
| Interface signals: | Digital, serial | ||
| Интерфейс для параметризации: | Data format: 1 start bit, 8 data bits, 1 stop bit, no parity, Data protocol: ASCII, Baud rate 9600 RS-422, RS-422, Four wire transmission, asynchrony, full duplex | ||
| Data format: | SSI 24 bits format | ||
| Standard (default setting SSI standard): | RS-422 off | ||
| Данные окуражающей среды | |||
| EMC: | (according to EN 61000-6-2 and EN 61000-6-4) 1) | ||
| Enclosure rating: | IP 66 (IEC 60529) | ||
| Working temperature range: | -20 °C ... +60 °C | ||
| Storage temperature range: | -40 °C ... +85 °C | ||
| Устойчивость к ударам: | 30 g, 10 ms (DIN EN 60 068-2-27) | ||
| Resistance to vibration: | 10 g, 20 Hz ... 250 Hz (EN 60068-2-6) | ||
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
| Performance | |||
| Measuring length: | 0 m ... 354 m | ||
| Measuring range: | 354 m | ||
| Resolution: | 0.1 mm | ||
| Piston speed: | 6.6 m/s 1) | ||
| Measurement accuracy: | ± 1000 + ME (Tu-25° C) Tk µm 2) | ||
| Repeatability (Ta not constant): | 0.3 mm | ||
| Mechanical data | |||
| Тип подключения: | Cable, 5 m | ||
| Масса: | 3.6 kg | ||
| Position tolerance: | ± 10 mm | ||
| Material: | AlMgSiPbF28 | ||
| Electrical data | |||
| Время инициализации: | 2 s | ||
| Время формирования позици: | 0.8 ms | ||
| Supply voltage: | 10 V ... 32 V | ||
| Потребляемая мощность: | 250 mA | ||
| MTTFd: mean time to dangerous failure: | 31 a (EN ISO 13849) 1) | ||
| Interfaces | |||
| Electrical interface: | SSI | ||
| Interface signals: | Digital, serial | ||
| Интерфейс для параметризации: | Data format: 1 start bit, 8 data bits, 1 stop bit, no parity, Data protocol: ASCII, Baud rate 9600 RS-422, RS-422, Four wire transmission, asynchrony, full duplex | ||
| Data format: | SSI 24 bits format | ||
| Standard (default setting SSI standard): | RS-422 off | ||
| Данные окуражающей среды | |||
| EMC: | (according to EN 61000-6-2 and EN 61000-6-4) 1) | ||
| Enclosure rating: | IP 66 (IEC 60529) | ||
| Working temperature range: | -20 °C ... +60 °C | ||
| Storage temperature range: | -40 °C ... +85 °C | ||
| Устойчивость к ударам: | 30 g, 10 ms (DIN EN 60 068-2-27) | ||
| Resistance to vibration: | 10 g, 20 Hz ... 250 Hz (EN 60068-2-6) | ||
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
| Performance | |||
| Measuring length: | 0 m ... 548 m | ||
| Measuring range: | 548 m | ||
| Resolution: | 0.1 mm | ||
| Piston speed: | 6.6 m/s 1) | ||
| Measurement accuracy: | ± 2000 + ME (Tu-25° C) Tk µm 2) | ||
| Repeatability (Ta not constant): | 1 mm | ||
| Mechanical data | |||
| Тип подключения: | Cable, 5 m | ||
| Масса: | 6.7 kg | ||
| Position tolerance: | ± 20 mm | ||
| Material: | AlMgSiPbF28 | ||
| Electrical data | |||
| Время инициализации: | 2 s | ||
| Время формирования позици: | 0.8 ms | ||
| Supply voltage: | 10 V ... 32 V | ||
| Потребляемая мощность: | 250 mA | ||
| MTTFd: mean time to dangerous failure: | 22 a (EN ISO 13849) 1) | ||
| Interfaces | |||
| Electrical interface: | SSI | ||
| Interface signals: | Digital, serial | ||
| Интерфейс для параметризации: | Data format: 1 start bit, 8 data bits, 1 stop bit, no parity, Data protocol: ASCII, Baud rate 9600 RS-422, RS-422, Four wire transmission, asynchrony, full duplex | ||
| Data format: | SSI 24 bits format | ||
| Standard (default setting SSI standard): | RS-422 off | ||
| Данные окуражающей среды | |||
| EMC: | (according to EN 61000-6-2 and EN 61000-6-4) 1) | ||
| Enclosure rating: | IP 66 (IEC 60529) | ||
| Working temperature range: | -30 °C ... +70 °C | ||
| Storage temperature range: | -40 °C ... +85 °C | ||
| Устойчивость к ударам: | 30 g, 10 ms (DIN EN 60 068-2-27) | ||
| Resistance to vibration: | 10 g, 20 Hz ... 250 Hz (EN 60068-2-6) | ||
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
| Performance | |||
| Measuring length: | 0 m ... 1,700 m | ||
| Measuring range: | 1,700 m | ||
| Resolution: | 0.1 mm | ||
| Piston speed: | 6.6 m/s 1) | ||
| Measurement accuracy: | ± 1000 + ME (Tu-25° C) Tk µm 2) | ||
| Repeatability (Ta not constant): | 0.3 mm | ||
| Mechanical data | |||
| Тип подключения: | Cable, 5 m | ||
| Масса: | 5.2 kg | ||
| Position tolerance: | ± 10 mm | ||
| Material: | AlMgSiPbF28 | ||
| Electrical data | |||
| Время инициализации: | 2 s | ||
| Время формирования позици: | 0.8 ms | ||
| Supply voltage: | 10 V ... 32 V | ||
| Потребляемая мощность: | 250 mA | ||
| MTTFd: mean time to dangerous failure: | 21 a (EN ISO 13849) 1) | ||
| Interfaces | |||
| Electrical interface: | SSI | ||
| Interface signals: | Digital, serial | ||
| Интерфейс для параметризации: | Data format: 1 start bit, 8 data bits, 1 stop bit, no parity, Data protocol: ASCII, Baud rate 9600 RS-422, RS-422, Four wire transmission, asynchrony, full duplex | ||
| Data format: | SSI 24 bits format | ||
| Standard (default setting SSI standard): | RS-422 off | ||
| Данные окуражающей среды | |||
| EMC: | (according to EN 61000-6-2 and EN 61000-6-4) 1) | ||
| Enclosure rating: | IP 66 (IEC 60529) | ||
| Working temperature range: | -20 °C ... +60 °C | ||
| Storage temperature range: | -40 °C ... +85 °C | ||
| Устойчивость к ударам: | 30 g, 10 ms (DIN EN 60 068-2-27) | ||
| Resistance to vibration: | 10 g, 20 Hz ... 250 Hz (EN 60068-2-6) | ||
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
| Performance | |||
| Measuring length: | 0 m ... 38 m | ||
| Measuring range: | 38 m | ||
| Resolution: | 0.1 mm | ||
| Piston speed: | 6.6 m/s 1) | ||
| Measurement accuracy: | ± 1000 + ME (Tu-25° C) Tk µm 2) | ||
| Repeatability (Ta not constant): | 0.3 mm | ||
| Mechanical data | |||
| Тип подключения: | Cable, 10 m | ||
| Масса: | 2.4 kg | ||
| Position tolerance: | ± 10 mm | ||
| Material: | AlMgSiPbF28 | ||
| Electrical data | |||
| Время инициализации: | 2 s | ||
| Время формирования позици: | 0.8 ms | ||
| Supply voltage: | 10 V ... 32 V | ||
| Потребляемая мощность: | 250 mA | ||
| MTTFd: mean time to dangerous failure: | 45 a (EN ISO 13849) 1) | ||
| Interfaces | |||
| Electrical interface: | SSI | ||
| Interface signals: | Digital, serial | ||
| Интерфейс для параметризации: | Data format: 1 start bit, 8 data bits, 1 stop bit, no parity, Data protocol: ASCII, Baud rate 9600 RS-422, RS-422, Four wire transmission, asynchrony, full duplex | ||
| Data format: | SSI 24 bits format | ||
| Standard (default setting SSI standard): | RS-422 off | ||
| Данные окуражающей среды | |||
| EMC: | (according to EN 61000-6-2 and EN 61000-6-4) 1) | ||
| Enclosure rating: | IP 66 (IEC 60529) | ||
| Working temperature range: | -20 °C ... +60 °C | ||
| Storage temperature range: | -40 °C ... +85 °C | ||
| Устойчивость к ударам: | 30 g, 10 ms (DIN EN 60 068-2-27) | ||
| Resistance to vibration: | 10 g, 20 Hz ... 250 Hz (EN 60068-2-6) | ||
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
| Performance | |||
| Measuring length: | 0 m ... 107 m | ||
| Measuring range: | 107 m | ||
| Resolution: | 0.1 mm | ||
| Piston speed: | 6.6 m/s 1) | ||
| Measurement accuracy: | ± 1000 + ME (Tu-25° C) Tk µm 2) | ||
| Repeatability (Ta not constant): | 0.3 mm | ||
| Mechanical data | |||
| Тип подключения: | Cable, 10 m | ||
| Масса: | 2.7 kg | ||
| Position tolerance: | ± 10 mm | ||
| Material: | AlMgSiPbF28 | ||
| Electrical data | |||
| Время инициализации: | 2 s | ||
| Время формирования позици: | 0.8 ms | ||
| Supply voltage: | 10 V ... 32 V | ||
| Потребляемая мощность: | 250 mA | ||
| MTTFd: mean time to dangerous failure: | 40 a (EN ISO 13849) 1) | ||
| Interfaces | |||
| Electrical interface: | SSI | ||
| Interface signals: | Digital, serial | ||
| Интерфейс для параметризации: | Data format: 1 start bit, 8 data bits, 1 stop bit, no parity, Data protocol: ASCII, Baud rate 9600 RS-422, RS-422, Four wire transmission, asynchrony, full duplex | ||
| Data format: | SSI 24 bits format | ||
| Standard (default setting SSI standard): | RS-422 off | ||
| Данные окуражающей среды | |||
| EMC: | (according to EN 61000-6-2 and EN 61000-6-4) 1) | ||
| Enclosure rating: | IP 66 (IEC 60529) | ||
| Working temperature range: | -20 °C ... +60 °C | ||
| Storage temperature range: | -40 °C ... +85 °C | ||
| Устойчивость к ударам: | 30 g, 10 ms (DIN EN 60 068-2-27) | ||
| Resistance to vibration: | 10 g, 20 Hz ... 250 Hz (EN 60068-2-6) | ||
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
| Performance | |||
| Measuring length: | 0 m ... 354 m | ||
| Measuring range: | 354 m | ||
| Resolution: | 0.1 mm | ||
| Piston speed: | 6.6 m/s 1) | ||
| Measurement accuracy: | ± 1000 + ME (Tu-25° C) Tk µm 2) | ||
| Repeatability (Ta not constant): | 0.3 mm | ||
| Mechanical data | |||
| Тип подключения: | Cable, 10 m | ||
| Масса: | 3.6 kg | ||
| Position tolerance: | ± 10 mm | ||
| Material: | AlMgSiPbF28 | ||
| Electrical data | |||
| Время инициализации: | 2 s | ||
| Время формирования позици: | 0.8 ms | ||
| Supply voltage: | 10 V ... 32 V | ||
| Потребляемая мощность: | 250 mA | ||
| MTTFd: mean time to dangerous failure: | 31 a (EN ISO 13849) 1) | ||
| Interfaces | |||
| Electrical interface: | SSI | ||
| Interface signals: | Digital, serial | ||
| Интерфейс для параметризации: | Data format: 1 start bit, 8 data bits, 1 stop bit, no parity, Data protocol: ASCII, Baud rate 9600 RS-422, RS-422, Four wire transmission, asynchrony, full duplex | ||
| Data format: | SSI 24 bits format | ||
| Standard (default setting SSI standard): | RS-422 off | ||
| Данные окуражающей среды | |||
| EMC: | (according to EN 61000-6-2 and EN 61000-6-4) 1) | ||
| Enclosure rating: | IP 66 (IEC 60529) | ||
| Working temperature range: | -20 °C ... +60 °C | ||
| Storage temperature range: | -40 °C ... +85 °C | ||
| Устойчивость к ударам: | 30 g, 10 ms (DIN EN 60 068-2-27) | ||
| Resistance to vibration: | 10 g, 20 Hz ... 250 Hz (EN 60068-2-6) | ||
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
| Performance | |||
| Measuring length: | 0 m ... 1,700 m | ||
| Measuring range: | 1,700 m | ||
| Resolution: | 0.1 mm | ||
| Piston speed: | 6.6 m/s 1) | ||
| Measurement accuracy: | ± 1000 + ME (Tu-25° C) Tk µm 2) | ||
| Repeatability (Ta not constant): | 0.3 mm | ||
| Mechanical data | |||
| Тип подключения: | Cable, 10 m | ||
| Масса: | 5.2 kg | ||
| Position tolerance: | ± 10 mm | ||
| Material: | AlMgSiPbF28 | ||
| Electrical data | |||
| Время инициализации: | 2 s | ||
| Время формирования позици: | 0.8 ms | ||
| Supply voltage: | 10 V ... 32 V | ||
| Потребляемая мощность: | 250 mA | ||
| MTTFd: mean time to dangerous failure: | 21 a (EN ISO 13849) 1) | ||
| Interfaces | |||
| Electrical interface: | SSI | ||
| Interface signals: | Digital, serial | ||
| Интерфейс для параметризации: | Data format: 1 start bit, 8 data bits, 1 stop bit, no parity, Data protocol: ASCII, Baud rate 9600 RS-422, RS-422, Four wire transmission, asynchrony, full duplex | ||
| Data format: | SSI 24 bits format | ||
| Standard (default setting SSI standard): | RS-422 off | ||
| Данные окуражающей среды | |||
| EMC: | (according to EN 61000-6-2 and EN 61000-6-4) 1) | ||
| Enclosure rating: | IP 66 (IEC 60529) | ||
| Working temperature range: | -20 °C ... +60 °C | ||
| Storage temperature range: | -40 °C ... +85 °C | ||
| Устойчивость к ударам: | 30 g, 10 ms (DIN EN 60 068-2-27) | ||
| Resistance to vibration: | 10 g, 20 Hz ... 250 Hz (EN 60068-2-6) | ||
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
| Performance | |||
| Measuring length: | 0 m ... 38 m | ||
| Measuring range: | 38 m | ||
| Resolution: | 0.1 mm | ||
| Piston speed: | 6.6 m/s 1) | ||
| Measurement accuracy: | ± 1000 + ME (Tu-25° C) Tk µm 2) | ||
| Repeatability (Ta not constant): | 0.3 mm | ||
| Mechanical data | |||
| Тип подключения: | 3 x connector M12 | ||
| Масса: | 2.4 kg | ||
| Position tolerance: | ± 10 mm | ||
| Material: | AlMgSiPbF28 | ||
| Electrical data | |||
| Время инициализации: | 2 s | ||
| Время формирования позици: | 1.1 ms | ||
| Supply voltage: | 10 V ... 32 V | ||
| Потребляемая мощность: | 2.5 W | ||
| MTTFd: mean time to dangerous failure: | 40 a (EN ISO 13849) 1) | ||
| Interfaces | |||
| Electrical interface: | PROFIBUS DP | ||
| Bus interface: | RS-485 1)2)3) | ||
| SET (electronic adjustment): | Via protocol | ||
| Address setting: | 0 ... 127, Hex switches or Protocol | ||
| Data protocol: | Profibus DP basic functions, Profile for encoders (07hex) - Class 2 | ||
| Status information: | Operation (LED green), Bus aktivity (LED red) | ||
| Bus termination: | Via external switches | ||
| Данные окуражающей среды | |||
| EMC: | (according to EN 61000-6-2 and EN 61000-6-4) 1) | ||
| Enclosure rating: | IP 67 (IEC 60529), with mating connector inserted | ||
| Working temperature range: | -20 °C ... +60 °C | ||
| Storage temperature range: | -40 °C ... +85 °C | ||
| Устойчивость к ударам: | 30 g, 10 ms (DIN EN 60 068-2-27) | ||
| Resistance to vibration: | 10 g, 20 Hz ... 250 Hz (EN 60068-2-6) | ||
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
| Performance | |||
| Measuring length: | 0 m ... 54 m | ||
| Measuring range: | 54 m | ||
| Resolution: | 0.1 mm | ||
| Piston speed: | 6.6 m/s 1) | ||
| Measurement accuracy: | ± 2000 + ME (Tu-25° C) Tk µm 2) | ||
| Repeatability (Ta not constant): | 1 mm | ||
| Mechanical data | |||
| Тип подключения: | 3 x connector M12 | ||
| Масса: | 4.4 kg | ||
| Position tolerance: | ± 20 mm | ||
| Material: | AlMgSiPbF28 | ||
| Electrical data | |||
| Время инициализации: | 2 s | ||
| Время формирования позици: | 1.1 ms | ||
| Supply voltage: | 10 V ... 32 V | ||
| Потребляемая мощность: | 2.5 W | ||
| MTTFd: mean time to dangerous failure: | 30 a (EN ISO 13849) 1) | ||
| Interfaces | |||
| Electrical interface: | PROFIBUS DP | ||
| Bus interface: | RS-485 1)2)3) | ||
| SET (electronic adjustment): | Via protocol | ||
| Address setting: | 0 ... 127, Hex switches or Protocol | ||
| Data protocol: | Profibus DP basic functions, Profile for encoders (07hex) - Class 2 | ||
| Status information: | Operation (LED green), Bus aktivity (LED red) | ||
| Bus termination: | Via external switches | ||
| Данные окуражающей среды | |||
| EMC: | (according to EN 61000-6-2 and EN 61000-6-4) 1) | ||
| Enclosure rating: | IP 67 (IEC 60529), with mating connector inserted | ||
| Working temperature range: | -30 °C ... +70 °C | ||
| Storage temperature range: | -40 °C ... +85 °C | ||
| Устойчивость к ударам: | 30 g, 10 ms (DIN EN 60 068-2-27) | ||
| Resistance to vibration: | 10 g, 20 Hz ... 250 Hz (EN 60068-2-6) | ||
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
| Performance | |||
| Measuring length: | 0 m ... 107 m | ||
| Measuring range: | 107 m | ||
| Resolution: | 0.1 mm | ||
| Piston speed: | 6.6 m/s 1) | ||
| Measurement accuracy: | ± 1000 + ME (Tu-25° C) Tk µm 2) | ||
| Repeatability (Ta not constant): | 0.3 mm | ||
| Mechanical data | |||
| Тип подключения: | 3 x connector M12 | ||
| Масса: | 2.7 kg | ||
| Position tolerance: | ± 10 mm | ||
| Material: | AlMgSiPbF28 | ||
| Electrical data | |||
| Время инициализации: | 2 s | ||
| Время формирования позици: | 1.1 ms | ||
| Supply voltage: | 10 V ... 32 V | ||
| Потребляемая мощность: | 2.5 W | ||
| MTTFd: mean time to dangerous failure: | 35 a (EN ISO 13849) 1) | ||
| Interfaces | |||
| Electrical interface: | PROFIBUS DP | ||
| Bus interface: | RS-485 1)2)3) | ||
| SET (electronic adjustment): | Via protocol | ||
| Address setting: | 0 ... 127, Hex switches or Protocol | ||
| Data protocol: | Profibus DP basic functions, Profile for encoders (07hex) - Class 2 | ||
| Status information: | Operation (LED green), Bus aktivity (LED red) | ||
| Bus termination: | Via external switches | ||
| Данные окуражающей среды | |||
| EMC: | (according to EN 61000-6-2 and EN 61000-6-4) 1) | ||
| Enclosure rating: | IP 67 (IEC 60529), with mating connector inserted | ||
| Working temperature range: | -20 °C ... +60 °C | ||
| Storage temperature range: | -40 °C ... +85 °C | ||
| Устойчивость к ударам: | 30 g, 10 ms (DIN EN 60 068-2-27) | ||
| Resistance to vibration: | 10 g, 20 Hz ... 250 Hz (EN 60068-2-6) | ||
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
| Performance | |||
| Measuring length: | 0 m ... 354 m | ||
| Measuring range: | 354 m | ||
| Resolution: | 0.1 mm | ||
| Piston speed: | 6.6 m/s 1) | ||
| Measurement accuracy: | ± 1000 + ME (Tu-25° C) Tk µm 2) | ||
| Repeatability (Ta not constant): | 0.3 mm | ||
| Mechanical data | |||
| Тип подключения: | 3 x connector M12 | ||
| Масса: | 3.6 kg | ||
| Position tolerance: | ± 10 mm | ||
| Material: | AlMgSiPbF28 | ||
| Electrical data | |||
| Время инициализации: | 2 s | ||
| Время формирования позици: | 1.1 ms | ||
| Supply voltage: | 10 V ... 32 V | ||
| Потребляемая мощность: | 2.5 W | ||
| MTTFd: mean time to dangerous failure: | 28 a (EN ISO 13849) 1) | ||
| Interfaces | |||
| Electrical interface: | PROFIBUS DP | ||
| Bus interface: | RS-485 1)2)3) | ||
| SET (electronic adjustment): | Via protocol | ||
| Address setting: | 0 ... 127, Hex switches or Protocol | ||
| Data protocol: | Profibus DP basic functions, Profile for encoders (07hex) - Class 2 | ||
| Status information: | Operation (LED green), Bus aktivity (LED red) | ||
| Bus termination: | Via external switches | ||
| Данные окуражающей среды | |||
| EMC: | (according to EN 61000-6-2 and EN 61000-6-4) 1) | ||
| Enclosure rating: | IP 67 (IEC 60529), with mating connector inserted | ||
| Working temperature range: | -20 °C ... +60 °C | ||
| Storage temperature range: | -40 °C ... +85 °C | ||
| Устойчивость к ударам: | 30 g, 10 ms (DIN EN 60 068-2-27) | ||
| Resistance to vibration: | 10 g, 20 Hz ... 250 Hz (EN 60068-2-6) | ||
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
| Performance | |||
| Measuring length: | 0 m ... 548 m | ||
| Measuring range: | 548 m | ||
| Resolution: | 0.1 mm | ||
| Piston speed: | 6.6 m/s 1) | ||
| Measurement accuracy: | ± 2000 + ME (Tu-25° C) Tk µm 2) | ||
| Repeatability (Ta not constant): | 1 mm | ||
| Mechanical data | |||
| Тип подключения: | 3 x connector M12 | ||
| Масса: | 6.7 kg | ||
| Position tolerance: | ± 20 mm | ||
| Material: | AlMgSiPbF28 | ||
| Electrical data | |||
| Время инициализации: | 2 s | ||
| Время формирования позици: | 1.1 ms | ||
| Supply voltage: | 10 V ... 32 V | ||
| Потребляемая мощность: | 2.5 W | ||
| MTTFd: mean time to dangerous failure: | 20 a (EN ISO 13849) 1) | ||
| Interfaces | |||
| Electrical interface: | PROFIBUS DP | ||
| Bus interface: | RS-485 1)2)3) | ||
| SET (electronic adjustment): | Via protocol | ||
| Address setting: | 0 ... 127, Hex switches or Protocol | ||
| Data protocol: | Profibus DP basic functions, Profile for encoders (07hex) - Class 2 | ||
| Status information: | Operation (LED green), Bus aktivity (LED red) | ||
| Bus termination: | Via external switches | ||
| Данные окуражающей среды | |||
| EMC: | (according to EN 61000-6-2 and EN 61000-6-4) 1) | ||
| Enclosure rating: | IP 67 (IEC 60529), with mating connector inserted | ||
| Working temperature range: | -30 °C ... +70 °C | ||
| Storage temperature range: | -40 °C ... +85 °C | ||
| Устойчивость к ударам: | 30 g, 10 ms (DIN EN 60 068-2-27) | ||
| Resistance to vibration: | 10 g, 20 Hz ... 250 Hz (EN 60068-2-6) | ||
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
| Performance | |||
| Measuring length: | 0 m ... 1,700 m | ||
| Measuring range: | 1,700 m | ||
| Resolution: | 0.1 mm | ||
| Piston speed: | 6.6 m/s 1) | ||
| Measurement accuracy: | ± 1000 + ME (Tu-25° C) Tk µm 2) | ||
| Repeatability (Ta not constant): | 0.3 mm | ||
| Mechanical data | |||
| Тип подключения: | 3 x connector M12 | ||
| Масса: | 5.2 kg | ||
| Position tolerance: | ± 10 mm | ||
| Material: | AlMgSiPbF28 | ||
| Electrical data | |||
| Время инициализации: | 2 s | ||
| Время формирования позици: | 1.1 ms | ||
| Supply voltage: | 10 V ... 32 V | ||
| Потребляемая мощность: | 2.5 W | ||
| MTTFd: mean time to dangerous failure: | 20 a (EN ISO 13849) 1) | ||
| Interfaces | |||
| Electrical interface: | PROFIBUS DP | ||
| Bus interface: | RS-485 1)2)3) | ||
| SET (electronic adjustment): | Via protocol | ||
| Address setting: | 0 ... 127, Hex switches or Protocol | ||
| Data protocol: | Profibus DP basic functions, Profile for encoders (07hex) - Class 2 | ||
| Status information: | Operation (LED green), Bus aktivity (LED red) | ||
| Bus termination: | Via external switches | ||
| Данные окуражающей среды | |||
| EMC: | (according to EN 61000-6-2 and EN 61000-6-4) 1) | ||
| Enclosure rating: | IP 67 (IEC 60529), with mating connector inserted | ||
| Working temperature range: | -20 °C ... +60 °C | ||
| Storage temperature range: | -40 °C ... +85 °C | ||
| Устойчивость к ударам: | 30 g, 10 ms (DIN EN 60 068-2-27) | ||
| Resistance to vibration: | 10 g, 20 Hz ... 250 Hz (EN 60068-2-6) | ||
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
| Mechanical data | |||
| Масса: | 0.5 kg per meter | ||
| Material: | AlMgSi0,5F22 | ||
| Electrical data | |||
| Code type: | Coded | ||
| Данные окуражающей среды | |||
| Устойчивость к ударам: | 50 g, 10 ms (DIN EN 61000-2-27) | ||
| Resistance to vibration: | 30 g, 20 Hz ... 250 Hz (DIN EN 61000-2-6) | ||
| Coefficient of thermal expansion: | 28 µm/°C/m | ||
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
| Mechanical data | |||
| Масса: | 0.65 kg per meter | ||
| Material: | AlMgSi0,5F22 | ||
| Electrical data | |||
| Code type: | Coded | ||
| Данные окуражающей среды | |||
| Устойчивость к ударам: | 50 g, 10 ms (DIN EN 61000-2-27) | ||
| Resistance to vibration: | 30 g, 20 Hz ... 250 Hz (DIN EN 61000-2-6) | ||
| Coefficient of thermal expansion: | 28 µm/°C/m | ||
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
| Mechanical data | |||
| Масса: | 0.5 kg per meter | ||
| Material: | AlMgSi0,5F22 | ||
| Electrical data | |||
| Code type: | Coded | ||
| Данные окуражающей среды | |||
| Устойчивость к ударам: | 50 g, 10 ms (DIN EN 61000-2-27) | ||
| Resistance to vibration: | 30 g, 20 Hz ... 250 Hz (DIN EN 61000-2-6) | ||
| Coefficient of thermal expansion: | 28 µm/°C/m | ||
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
| Mechanical data | |||
| Масса: | Per meter | ||
| Material: | AlMgSi0,5F22 | ||
| Electrical data | |||
| Code type: | Coded | ||
| Данные окуражающей среды | |||
| Устойчивость к ударам: | 50 g, 10 ms (DIN EN 61000-2-27) | ||
| Resistance to vibration: | 30 g, 20 Hz ... 250 Hz (DIN EN 61000-2-6) | ||
| Coefficient of thermal expansion: | 28 µm/°C/m | ||
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
| Mechanical data | |||
| Масса: | 0.65 kg per meter | ||
| Material: | AlMgSi0,5F22 | ||
| Electrical data | |||
| Code type: | Coded | ||
| Данные окуражающей среды | |||
| Устойчивость к ударам: | 50 g, 10 ms (DIN EN 61000-2-27) | ||
| Resistance to vibration: | 30 g, 20 Hz ... 250 Hz (DIN EN 61000-2-6) | ||
| Coefficient of thermal expansion: | 28 µm/°C/m | ||
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
| Mechanical data | |||
| Масса: | 0.5 kg per meter | ||
| Material: | AlMgSi0,5F22 | ||
| Electrical data | |||
| Code type: | Coded | ||
| Данные окуражающей среды | |||
| Устойчивость к ударам: | 50 g, 10 ms (DIN EN 61000-2-27) | ||
| Resistance to vibration: | 30 g, 20 Hz ... 250 Hz (DIN EN 61000-2-6) | ||
| Coefficient of thermal expansion: | 28 µm/°C/m | ||
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
| Mechanical data | |||
| Масса: | 0.5 kg per meter | ||
| Material: | AlMgSi0,5F22 | ||
| Electrical data | |||
| Code type: | Universal configurable | ||
| Данные окуражающей среды | |||
| Устойчивость к ударам: | 50 g, 10 ms (DIN EN 61000-2-27) | ||
| Resistance to vibration: | 30 g, 20 Hz ... 250 Hz (DIN EN 61000-2-6) | ||
| Coefficient of thermal expansion: | 28 µm/°C/m | ||
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
| Mechanical data | |||
| Масса: | 0.65 kg per meter | ||
| Material: | AlMgSi0,5F22 | ||
| Electrical data | |||
| Code type: | Universal configurable | ||
| Данные окуражающей среды | |||
| Устойчивость к ударам: | 50 g, 10 ms (DIN EN 61000-2-27) | ||
| Resistance to vibration: | 30 g, 20 Hz ... 250 Hz (DIN EN 61000-2-6) | ||
| Coefficient of thermal expansion: | 28 µm/°C/m | ||
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
| Mechanical data | |||
| Масса: | 0.5 kg per meter | ||
| Material: | AlMgSi0,5F22 | ||
| Electrical data | |||
| Code type: | Universal configurable | ||
| Данные окуражающей среды | |||
| Устойчивость к ударам: | 50 g, 10 ms (DIN EN 61000-2-27) | ||
| Resistance to vibration: | 30 g, 20 Hz ... 250 Hz (DIN EN 61000-2-6) | ||
| Coefficient of thermal expansion: | 28 µm/°C/m | ||
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
| Mechanical data | |||
| Масса: | 0.5 kg per meter | ||
| Material: | AlMgSi0,5F22 | ||
| Electrical data | |||
| Code type: | Universal configurable | ||
| Данные окуражающей среды | |||
| Устойчивость к ударам: | 50 g, 10 ms (DIN EN 61000-2-27) | ||
| Resistance to vibration: | 30 g, 20 Hz ... 250 Hz (DIN EN 61000-2-6) | ||
| Coefficient of thermal expansion: | 28 µm/°C/m | ||
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
| Mechanical data | |||
| Масса: | 0.65 kg per meter | ||
| Material: | AlMgSi0,5F22 | ||
| Electrical data | |||
| Code type: | Universal configurable | ||
| Данные окуражающей среды | |||
| Устойчивость к ударам: | 50 g, 10 ms (DIN EN 61000-2-27) | ||
| Resistance to vibration: | 30 g, 20 Hz ... 250 Hz (DIN EN 61000-2-6) | ||
| Coefficient of thermal expansion: | 28 µm/°C/m | ||
At a glance
| Non-contact length measurement - maintenance-free, rugged, long lifetime |
| High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm) |
| SSI and PROFIBUS interfaces |
| Determination of absolute position |
| Measuring lengths of up to 1,700 m possible |
| Can be used in harsh environments |
| High travel speeds of up to 6.6 m/s |
| Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible |
Your benefits
| After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings. |
| Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations |
| High efficiency and productivity |
| Savings on time - no reference run necessary on initial operation due to absolute position measurement |
| accurate positioning even with high mounting tolerances |
| Mechanical data | |||
| Масса: | 0.5 kg per meter | ||
| Material: | AlMgSi0,5F22 | ||
| Electrical data | |||
| Code type: | Universal configurable | ||
| Данные окуражающей среды | |||
| Устойчивость к ударам: | 50 g, 10 ms (DIN EN 61000-2-27) | ||
| Resistance to vibration: | 30 g, 20 Hz ... 250 Hz (DIN EN 61000-2-6) | ||
| Coefficient of thermal expansion: | 28 µm/°C/m | ||