At a glance
| Flexible mounting on all standard profiles |
| Flexible PROFINET IO connection via two M12 plug connectors |
| Code switch for setting the operating mode |
| Six LEDs for status and diagnostics |
| Plug-in electrical connections |
| Integrated configuration memory for connected sensors |
| Compact and flexible |
Your benefits
| Sophisticated two-screw system for fast, flexible mounting on all standard profiles |
| Integrated switch for easy implementation of line topologies |
| Code switch that is mounted so it is protected against accidental adjustment and is easily accessible from the outside for easy setup of operating mode without complex software |
| Clear status LEDs that are identifiable on two sides from any viewing direction for simple and effective diagnosis |
| Fast installation and easy replacement in the system thanks to plug-in connections |
| Integrated cloning module for all configurations of the connected sensor enables very fast replacement time in case of faults |
| Compact and rugged design with choice of horizontal or vertical cable direction |
| Features | |||
| Краткое описание: | Fieldbus proxy/gateway for connecting one identification sensor to PROFINET-IO networks (interface 2 x M12, female connector/female connector, 4-pin) | ||
| Поддерживаемые продукты: | CLV61x, CLV62x, CLV63x, CLV64x, CLV65x, CLV69x, IDM12x, IDM14x, IDM16x, IDM24x, IDM26x, Lector®62x, RFH6xx, RFU63x | ||
| Supports cloning module (CMC): | Integrated | ||
| Supports display module (CMD): | No | ||
| Supports power supply module (CMP): | No | ||
| Supports fieldbus gateway (CMF): | Integrated (PROFINET IO) | ||
| Interfaces | |||
| Serial (RS-232): | ![]() |
||
| Function (Serial (RS-232)): | AUX | ||
| Data transmission rate (Serial (RS-232)): | 57.6 kBaud | ||
| Ethernet: | ![]() |
||
| Function (Ethernet): | Slave | ||
| Data transmission rate (Ethernet): | 2-port Ethernet in accordance with IEEE 802.3 (baud rate 100 MBit/s, full-duplex transmission, 2-port switch, auto-negotiation, auto-crossover). Maximum data length is limited by the mode of communication (fragmentation protocol) to 4,000 bytes. | ||
| Protocol (Ethernet): | PROFINET | ||
| CAN bus: | ![]() |
||
| Remark (CAN bus): | Depending on sensor connected | ||
| PROFIBUS DP: | - | ||
| DeviceNet: | - | ||
| Switching inputs: | 1 | ||
| Switching outputs: | 0 | ||
| Оптический индикатор: | 6 LEDs | ||
| Конфигурация программного обеспечения: | SOPAS ET | ||
| Механика/электроника | |||
| Electrical connection: | 1 x “DEVICE†connection, 15-pin D-sub HD female connector with seal, 1 x “EXT. IN 1†connection, 5-pin M12 female connector, A-coded, 1 x “POWER†connection, 5-pin M12 plug, A-coded, 1 x “PROFINET P1†connection, 4-pin M12 socket, D-coded, 1 x “PROFINET P2†connection, 4-pin M12 socket, D-coded, 1 x “USB†connection, 5-pin micro-B socket, for configuration/diagnostics, behind screw-mounted cover | ||
| Operating voltage: | 10 V DC ... 30 V DC | ||
| Потребляемая мощность: | |||
| Housing: | Aluminum (unpainted) | ||
| Enclosure rating: | IP 65 (EN 60068-2-17 (1995-05)) | ||
| Класс защиты: | III (EN 60950-1 (2011-01)) | ||
| Вес: | 361 g | ||
| Dimensions: | 207 mm x 49.5 mm x 40.7 mm | ||
| Цвет корпуса: | Aluminum (unpainted) | ||
| Подключения сканера: | RS-232 | ||
| Данные окуражающей среды | |||
| Electromagnetic compatibility (EMC): | EN 61000-6-3 (2011-09) / EN 61000-6-2 (2006-03) | ||
| Виброустойчивость: | EN 60068-2-6 (2008-10) | ||
| Ударопрочность: | EN 60068-2-27 (2010-02) | ||
| Ambient operating temperature: | -35 °C ... +50 °C | ||
| Storage temperature: | -35 °C ... +70 °C | ||
| Permissible relative humidity: | 90 %, non-condensing | ||