| Applications | |||
| Hazardous area protection (vertical): | ![]() |
||
| Access protection (vertical): | ![]() |
||
| Hazardous area protection (horizontal): | ![]() |
||
| Functions | |||
| Number of simultaneously monitored protective fields: | 2 | ||
| Incremental encoder inputs: | - | ||
| External device monitoring (EDM): | - | ||
| Integrated configuration memory: | ![]() |
||
| Expanded measured data output (CMS): | - | ||
| Measured data output: | - | ||
| Safe SICK device communication via EFI/SDL: | - | ||
| Technical data | |||
| Enclosure rating: | IP 65 (EN 60529) | ||
| Класс защиты: | III (VDE 0106, EN 60950) | ||
| Type: | Type 3 (IEC 61496) | ||
| Safety integrity level: | SIL2 (IEC 61508), SILCL2 (EN 62061) | ||
| Category: | Category 3 (EN ISO 13849) | ||
| Уровень производительности: | PL d (EN ISO 13849) | ||
| PFHd: | 8.0 * 1E-08 (EN ISO 13849) | ||
| TM (mission time): | 20 a (EN ISO 13849) | ||
| Ambient operating temperature: | -10 °C ... +50 °C | ||
| Response time: | 60 ms 1) | ||
| Electrical connection: | System plug with or without connecting cable | ||
| Supply voltage: | 16.8 V DC, 24 V DC, 28.8 V DC | ||
| Configuration and diagnostics interface: | RS-232 | ||
| Device properties: | GSDML according to GSDML specification V2.25, PROFINET IO module with 2-port real-time switch according to PROFINET specification V2.2, PROFIsafe profile with 6-octet input and 6-octet output according to IEC 61784-3-3 V2.4, Cycle time 4, 8, 16, 32 ms, etc. | ||
| Switch properties: | Filtering Data Base according to IEEE 802.1D 6 prioritization levels for IEEE 802.1Q - Network prioritization 64 KB SRAM memory for caching telegrams, managed in 768-byte segments Resource prioritization for network control and RTC2/3 frames Telegram extension based on "Cut-through" Port status (Disabled, Blocking, Forwarding) Support for non-real-time and real-time data transfer |
||
| Port properties: | Auto-negotiation Auto-crossover (MDIX) Auto-polarity 100Base-TX |
||
| Conformance: | Conformance Class B | ||
| Topology support: | SNMP, MIB-2, LLDP nach IEEE 802.1AB MRP client support |
||
| Diagnostics: | Application-related manufacturer-specific channel diagnostics and channel diagnostics for the PROFIsafe profile, individually switchable Report system errors Cable diagnostics Neighborhood alerts Support for port statistics I&M support from I&M0 to I&M4 |
||
| Interfaces for configuration and diagnostics using CDS: | TCP port 9000 and UDP port 30718 RS-232 |
||
| Functions that are not supported: | Multicast communication Supervisor AR MAC-pause mechanism in full duplex Back-pressure in half duplex Static learning Broadcast Storm Control |
||