At a glance
| Detection of magnets |
| Operating distances up to 60 mm or more based on the magnet strength |
| NAMUR as per EN 60 947-5-6 |
| High switching frequency |
| Rugged nickel-plated brass housing with fine thread M12 x 1 mm |
| IP 67 enclosure rating |
| EC-type test certificate Ex II 2G EEx ib IIC T6 TÜV 99 ATEX 1398 |
| Cylindrical design |
Your benefits
| NAMUR design ensures safe operation in highly explosive areas |
| Non-contact operation ensures resistance to dirt, dust and vibration, increasing sensor life and reducing maintenance costs |
| Large operating distances ensure reliable switching, even with target position tolerances |
| Non-contact, universal detection through several substances, including plastic containers and pipes and protective PTFE walls |
| Features | |||
| Thread size: | M12 x 1 | ||
| Housing: | Cylindrical | ||
| Sensing range Sn: | 60 mm 1) | ||
| Assured sensing range Sa: | 48.6 mm | ||
| Magnetic sensitivity: | ≤ 1 mT | ||
| Частота переключений: | 5,000 Hz | ||
| Output type: | NAMUR | ||
| Electrical wiring: | NAMUR | ||
| Enclosure rating: | IP 67 2) | ||
| Magnetic alignment: | Axial | ||
| Тип подключения: | Connector M12, 4-pin | ||
| Output characteristic: | Control courrent depending on switching state according to NAMUR EN 60947-5-6 | ||
| Механика/электроника | |||
| Длина корпуса: | 62.5 mm | ||
| Пульсации: | ≤ 5 % 1) | ||
| Hysteresis: | 1 % ... 10 % | ||
| Повторяемость: | ≤ 1 % 2) | ||
| Температурный дрейфт: | ± 10 % | ||
| EMC: | According to EN 60947-5-2 | ||
| Момент затяжки, Макс.: | ≤ 7 Nm | ||
| Защита от обратной полярности: | ![]() |
||
| защита от короткого замыкания: | ![]() |
||
| Материал корпуса: | Metal, Nickel-plated brass | ||
| Time delay before availability: | ≤ 2 ms | ||
| Ambient operating temperature: | -25 °C ... 75 °C | ||
| Ударная и вибрационная устойчивость: | 30 g, 11 ms / 10 ... 55 Hz, 1 mm | ||
| Current consumption, sensor is activated: | ≥ 2.5 mA | ||
| Current consumption, sensor is not activated: | ≤ 1 mA | ||
| Cable resistance: | ≤ 50 Ω | ||
| EC Approval Certificate: | TÜV 99 ATEX 1398 | ||
| ATEX marking: | EX II 2G Ex ia IIC T6 Ta: -20 °C ... 70 °C | ||
| Ex area category: | 2G | ||
| Input voltage Ui max.: | 16 V 3) | ||
| Input power Pi max.: | 100 mW 4) | ||
| Input current Ii max.: | 30 mA 5) | ||
| Internal capacitance Ci max.: | 15 nF 6) | ||
| Internal inductance Li max.: | 35 µH 7) | ||
| Nominal voltage: | 8.2 V DC | ||
| Wire-break protection: | 1 | ||
| Items supplied: | Fastening nuts (2 x) | ||
At a glance
| Detection of magnets |
| Operating distances up to 60 mm or more based on the magnet strength |
| NAMUR as per EN 60 947-5-6 |
| High switching frequency |
| Rugged nickel-plated brass housing with fine thread M12 x 1 mm |
| IP 67 enclosure rating |
| EC-type test certificate Ex II 2G EEx ib IIC T6 TÜV 99 ATEX 1398 |
| Cylindrical design |
Your benefits
| NAMUR design ensures safe operation in highly explosive areas |
| Non-contact operation ensures resistance to dirt, dust and vibration, increasing sensor life and reducing maintenance costs |
| Large operating distances ensure reliable switching, even with target position tolerances |
| Non-contact, universal detection through several substances, including plastic containers and pipes and protective PTFE walls |
| Features | |||
| Thread size: | M12 x 1 | ||
| Housing: | Cylindrical | ||
| Sensing range Sn: | 60 mm 1) | ||
| Assured sensing range Sa: | 48.6 mm | ||
| Magnetic sensitivity: | 1 mT | ||
| Частота переключений: | 5,000 Hz | ||
| Output type: | NAMUR | ||
| Electrical wiring: | NAMUR | ||
| Enclosure rating: | IP 67 2) | ||
| Magnetic alignment: | Axial | ||
| Тип подключения: | Cable, 2-wire, 2 m 3) | ||
| Output characteristic: | Control courrent depending on switching state according to NAMUR EN 60947-5-6 | ||
| Механика/электроника | |||
| Пульсации: | ≤ 5 % 1) | ||
| Hysteresis: | 1 % ... 10 % | ||
| Повторяемость: | ≤ 1 % 2) | ||
| Температурный дрейфт: | ± 10 % | ||
| EMC: | According to EN 60947-5-2 | ||
| Момент затяжки, Макс.: | ≤ 7 Nm | ||
| Защита от обратной полярности: | ![]() |
||
| защита от короткого замыкания: | ![]() |
||
| Материал корпуса: | Metal, Nickel-plated brass | ||
| Time delay before availability: | ≤ 2 ms | ||
| Ambient operating temperature: | -25 °C ... 75 °C | ||
| Ударная и вибрационная устойчивость: | 30 g, 11 ms / 10 ... 55 Hz, 1 mm | ||
| Материал кабеля: | PVC | ||
| Current consumption, sensor is activated: | ≥ 2.5 mA | ||
| Current consumption, sensor is not activated: | ≤ 1 mA | ||
| Cable resistance: | ≤ 50 Ω | ||
| EC Approval Certificate: | TÜV 99 ATEX 1398 | ||
| ATEX marking: | EX II 2G Ex ia IIC T6 Ta: -20 °C ... 70 °C | ||
| Ex area category: | 2G | ||
| Input voltage Ui max.: | 16 V 3) | ||
| Input power Pi max.: | 100 mW 4) | ||
| Input current Ii max.: | 30 mA 5) | ||
| Internal capacitance Ci max.: | 15 nF 6) | ||
| Internal inductance Li max.: | 35 µH 7) | ||
| Nominal voltage: | 8.2 V DC | ||
| Сечение провода: | 0.34 mm² | ||
| Wire-break protection: | 1 | ||
| Items supplied: | Fastening nuts (2 x) | ||
At a glance
| Detection of magnets |
| Operating distances up to 60 mm or more based on the magnet strength |
| NAMUR as per EN 60 947-5-6 |
| High switching frequency |
| Rugged nickel-plated brass housing with fine thread M12 x 1 mm |
| IP 67 enclosure rating |
| EC-type test certificate Ex II 2G EEx ib IIC T6 TÜV 99 ATEX 1398 |
| Cylindrical design |
Your benefits
| NAMUR design ensures safe operation in highly explosive areas |
| Non-contact operation ensures resistance to dirt, dust and vibration, increasing sensor life and reducing maintenance costs |
| Large operating distances ensure reliable switching, even with target position tolerances |
| Non-contact, universal detection through several substances, including plastic containers and pipes and protective PTFE walls |
| Features | |||
| Thread size: | M12 x 1 | ||
| Housing: | Cylindrical | ||
| Sensing range Sn: | 90 mm 1) | ||
| Assured sensing range Sa: | 72.9 mm | ||
| Magnetic sensitivity: | 0.6 mT | ||
| Частота переключений: | 5,000 Hz | ||
| Output type: | NAMUR | ||
| Electrical wiring: | NAMUR | ||
| Enclosure rating: | IP 67 2) | ||
| Magnetic alignment: | Axial | ||
| Тип подключения: | Cable, 4-wire, 0.8 m | ||
| Output characteristic: | Control courrent depending on switching state according to NAMUR EN 60947-5-6 | ||
| Механика/электроника | |||
| Длина корпуса: | 50 mm | ||
| Пульсации: | ≤ 5 % 1) | ||
| Hysteresis: | 1 % ... 10 % | ||
| Повторяемость: | ≤ 1 % 2) | ||
| Температурный дрейфт: | ± 10 % | ||
| EMC: | According to EN 60947-5-2 | ||
| Момент затяжки, Макс.: | ≤ 7 Nm | ||
| Защита от обратной полярности: | ![]() |
||
| защита от короткого замыкания: | ![]() |
||
| Материал корпуса: | Metal, Nickel-plated brass | ||
| Time delay before availability: | ≤ 2 ms | ||
| Ambient operating temperature: | -25 °C ... 75 °C | ||
| Ударная и вибрационная устойчивость: | 30 g, 11 ms / 10 ... 55 Hz, 1 mm | ||
| Current consumption, sensor is activated: | ≥ 2.5 mA | ||
| Current consumption, sensor is not activated: | ≤ 1 mA | ||
| Cable resistance: | ≤ 50 Ω | ||
| EC Approval Certificate: | TÜV 99 ATEX 1398 | ||
| ATEX marking: | EX II 2G Ex ia IIC T6 Ta: -20 °C ... 70 °C | ||
| Ex area category: | 2G | ||
| Input voltage Ui max.: | 16 V 3) | ||
| Input power Pi max.: | 100 mW 4) | ||
| Input current Ii max.: | 30 mA 5) | ||
| Internal capacitance Ci max.: | 15 nF 6) | ||
| Internal inductance Li max.: | 35 µH 7) | ||
| Nominal voltage: | 8.2 V DC | ||
| Wire-break protection: | 1 | ||
| Items supplied: | Fastening nuts (2 x) | ||